HK-0811 Unused hydrocarbon insulating oil Oxidation stability tester

Brand : HK
Product origin : China
Delivery time : within 30 days after recieving full TT payment
Supply capacity : 100set/month

The HK-0811 unused hydrocarbon insulating oil Oxidation stability tester complies with the requirements of the NB/SH/T 0811 test method and is suitable for determining the oxidation stability of unused hydrocarbon insulating oil under accelerated oxidation conditions. This standard is applicable to unused, uninhibited and inhibitor added mineral insulating oils.

Overview

     The HK-0811 unused hydrocarbon insulating oil Oxidation stability tester complies with the requirements of the NB/SH/T 0811 test method and is suitable for determining the oxidation stability of unused hydrocarbon insulating oil under accelerated oxidation conditions. This standard is applicable to unused, uninhibited and inhibitor added mineral insulating oils.



Functional features

1. This instrument adopts an integrated formed metal bath heating method, without the need to add other media. It is energy-saving and environmentally friendly, easy to use, and has high temperature control accuracy, fully covering the required temperature for experiments

The complete integrated design consists of a controller and a metal bath system

High-precision imported digital display temperature controller, 12 sets of imported independent high-precision flowmeters for display, and independent operation of experiments to ensure that the experimental results do not interfere with each other

PID control can quickly maintain stability after reaching the target temperature, saving waiting time

5   This device is equipped with an over-temperature protection device, making it more reliable and safe to use

It is equipped with a timer for automatic timing

High-precision needle valves ensure the accuracy of the intake air flow

Equipped with 12 sets of original German Masterflex precision flowmeters of model 03227-00



Technical parameters

Working power supply: AC 220V±10%, 50Hz±10%

Temperature control method: Built-in digital display temperature control meter for automatic temperature control

3 Temperature control range: Room temperature to 160℃

4 Temperature control accuracy: ±0.5℃ of the set temperature

Temperature measurement element: High-precision digital sensor

Sample quantity: 12 channels, and 12 samples can be tested simultaneously

Oxidation stability tester

Unused hydrocarbon insulating oil